정밀급 교정온도계
1560 Black Stack
The Hart Scientific 1560 Black Stack thermometer readout has established itself as one of the most versatile, cost-effective, accurate readouts in the world.
Nothing about the Hart Scientific 1560 Black Stack thermometer readout says ordinary. Traditionally, thermometers were square boxes configured to do one particular job - such as read a calibrated PRT. However, if you also wanted to measure thermistors, you had to buy another instrument that could do this specific task. Some thermometers can do multiple jobs, but they're expensive, complex, and difficult to use. You're paying for functions you don't need and may never use. The Hart Scientific 1560 Black Stack thermometer readout solves these problems and more.
The Hart Scientific 1560 Black Stack thermometer readout can be any kind of thermometer you want it to be, and it works in three distinctive ways. First, the Hart Scientific 1560 Black Stack thermometer readout a reference thermometer with a NIST traceable calibration; second, it's an automated calibration system reading your reference probe and sensors you're testing; third, it's a high-accuracy data acquisition system. And the Hart Scientific 1560 Black Stack thermometer readout does each of these functions better than any other thermometer currently on the market.
The Hart Scientific 1560 Black Stack thermometer readout works in unison with up to eight different modules that fit together to create a system that will do any type of thermometry you choose. You can buy all of them, or any combination of them, and change the Hart Scientific 1560 Black Stack thermometer readout and its functions anytime you want.
Each module stacks behind the preceding one, and when you add a module, the Hart Scientific 1560 Black Stack thermometer readout's software automatically reconfigures itself to include all of the new functions supplied by that module. There's nothing to take apart. No boards need to be installed. There's no software to load, and nothing has to be calibrated. Just stack a new module onto the back of the previous modules and you're ready to use the Hart Scientific 1560 Black Stack thermometer readout and all of its remarkable features.
The new Hart Scientific 9935 Multi Channel LogWare II software makes the Hart Scientific 1560 Black Stack thermometer readout an even more powerful data acquisition tool. LogWare II provides graphical and statistical analysis of each channel you're measuring (up to 96 with the Black Stack). And with alarms that can be customized, delayed start times, and selectable logging intervals, LogWare II turns the Hart Scientific 1560 Black Stack thermometer readout into the most powerful temperature data acquisition tool on the market.
The Base Unit
The Hart Scientific 1560 Black Stack thermometer readout starts with a base module. It consists of two parts: a display with the main processor and a power supply. The base module supplies power, communication management, and software coordination for all of the other modules. It has the display, control buttons, and RS-232 port built-in.
Each base Hart Scientific 1560 Black Stack thermometer readout can handle eight thermometer modules stacked behind it with a maximum of 96 sensor inputs. The base module never needs calibration and performs its own diagnostic self-test each time it powers up. The thermometer characteristics of each base module are defined by the thermometry modules stacked behind it.
The Modules
There are nine thermometry modules: an SPRT module, a high-temp PRT module, a PRT scanner module, a standards thermistor module, two 1000-ohm PRT modules, a thermistor scanner module, a precision thermocouple module, and a thermocouple scanner module.
Each module has its own processor and connects to the stack on a proprietary digital bus. Each retains its own calibration data and performs all analog measurement functions within the module.
No modules are included with the Hart Scientific 1560 Black Stack thermometer readout and must be purchased separately.
-
PRT Module 2560
The SPRT module reads 25-ohm and 100-ohm four-wire RTDs, PRTs, and SPRTs with very high accuracy. It turns the Hart Scientific 1560 Black Stack thermometer readout into a first-rate reference thermometer with an accuracy to ±0.005°C.
It has two input channels so you can collect data with two reference sensors, or you can do comparison calibrations of one sensor against a calibrated reference sensor.
Temperature conversion features include direct resistance measurement, ITS-90, W(T90), IPTS-68, Callendar-Van Dusen, or an RTD polynomial conversion. The user-changeable default values for the CVD conversion fit the 100-ohm, 0.00385 ALPHA sensor described by IEC-751.
The SPRT modules can be used one at a time or combined together in any combination for reading up to 16 different reference thermometers. If you stack an SPRT module with a scanner module, you can test multiple sensors against your reference. Unlike other competitive instruments, the Hart Scientific PRT Scanner Module operates with or without the two-channel SPRT module. If you can think of a way to use a reference thermometer, you can do it with the Black Stack.
-
High-Temp PRT Module 2561
This module reads 2.5-ohm and 0.25-ohm four-wire HTPRTs and RTDs. The complete resistance range covers up to 5-ohm sensors with applications as high as 1200°C. The temperature conversion features are the same as for the SPRT module, and like the SPRT module, the connectors are gold plated.
-
PRT Scanner 2562
This module reads eight channels of two-, three- or four-wire 100-ohm PRTs or RTDs. The accuracy is ±0.01°C at 0°C for calibration of industrial sensors. The common industrial RTD can be read with the default values in the CVD temperature conversion for fast setup of industrial applications, or you can enter individual probe constants for higher accuracy data acquisition.
-
1000-Ohm PRT Modules 2567 and 2568
For 1000-ohm PRTs, these modules provide all the same great features as the 2560 and 2562 Modules. The two-channel 2567 Module has a resistance range of 0 to 4000 ohms and is accurate to ±0.006°C at 0°C. The 2568 Module reads up to eight 1000-ohm PRTs and at 0°C is accurate to ±0.01°C. Don't use an ohmmeter or multimeter to read your 1000-ohm PRTs when you can use a Hart Scientific 1560 Black Stack thermometer readout loaded with convenient temperature functions.
-
Standards Thermistor Module 2563
Special low-drift thermistors are becoming increasingly popular as reference probes in applications with modest temperature ranges up to 100°C. This module has a temperature accuracy of ±0.0013°C at 0°C with a resolution of 0.0001°C.
The 2563 Thermistor Module has two input channels. It displays direct resistance in ohms or converts directly to a temperature readout using either the Steinhart-Hart equation or a higher-order polynomial.
-
Thermistor Scanner Module 2564
This module is usable with any type of thermistor but has eight channels instead of the two channels found on the Standards Thermistor Module and operates with or without the Standards Thermistor Module. This module's accuracy is ±0.0025°C at 0°C for all eight channels.
The eight channels make the 2564 module an excellent data acquisition tool. It can be used in research work or for verification of biomedical equipment such as DNA sequencing apparatus.
-
Precision Thermocouple Module 2565
This precision thermocouple module reads any type of thermocouple, including type S platinum thermocouples and the new gold-platinum thermocouples for standards work. This two-channel module has internal cold junction compensation, or you can use an external source for even greater accuracy.
All the standard ANSI thermocouple types are preprogrammed; however, you can choose a conversion method and then enter the probe characteristics of your sensor, creating a system-calibrated channel. The 2565 module accepts up to three calibration points for error adjustment in the individual sensor. A polynomial interpolation function calculates the points between your measurements.
Type R, type S, and gold-platinum conversions accept complete polynomial calibration coefficients. Additionally, a thermocouple conversion function calculates temperature by interpolating from a table. You enter the temperature in degrees C and the corresponding voltage for your specific sensor from 1 to 10 temperatures. Interpolation is performed between the entered points.
-
Thermocouple Scanner Module 2566
This module has 12 channels and reads K, J, T, S, R, B, E, and N thermocouples. Each channel can be set to read a different type of thermocouple. All temperature readings are performed in exactly the same manner as with the 2565 module.
The connectors on the scanner module are special dual connectors that accept both the common miniature and standard thermocouple connectors. If you want to use screw terminals, use the appropriately-sized connector with the hood removed.
The Hart Scientific 1560 Black Stack thermometer readout is an incredible thermometer. You buy only the modules you need for the work you are doing. If your work changes, simply order the modules with the functions you need and slip them onto the back of the Hart Scientific 1560 Black Stack thermometer readout. Your thermometer changes its software, display, and method of operation to match the new functions you've added.
|